Doepfer A-176 Triple Control Voltage Source Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Audio Doepfer A-176 Triple Control Voltage Source. Doepfer A-176 Triple Control Voltage Source User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 6
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
doepfer
System A - 100
Control Voltage Source A-176
1
1. Introduction
Module A-176 (Control Voltage Source) provides
three
voltage sources
, to use wherever an extra CV
is required.
The top two voltage sources (CV 1 and CV 2) have
controls for
coarse
and
fine
control of the voltage
output; the third source (CV 3) just has the one control.
The range of the voltages output can be preset, either
to
0 to +5 V
or to
-2.5 V to +2.5 V
depending on your
likely requirements. There is a jumper on the circuit
board for each of the three voltage sources.
A typical use for the module would be to provide fine
as well as coarse tuning for an A-110 standard VCO,
(which, unlike the A-111, only has one tune control),
See chapter 5, user examples.
In general, this module will be useful whenever you
need a manually controllable CV on a module which
doesn’t itself have a built-in control.
CV 3
Contr. Volt. Source
CV 1
Fine
CV 3
CV 1
CV 2
Fine
CV 2
Zobrazit stránku 0
1 2 3 4 5 6

Shrnutí obsahu

Strany 1 - 1. Introduction

doepferSystem A - 100Control Voltage Source A-17611. IntroductionModule A-176 (Control Voltage Source) providesthree voltage sources, to use wher

Strany 2 - 2. Overview

A-176 Control Voltage SourceSystem A - 100doepfer22. OverviewControls:1 CV 1 : Coarse control for the voltage atlinked outputs ! and "2 Fin

Strany 3 - 4. Outputs

doepferSystem A - 100Control Voltage Source A-17633. Controls1 CV 1 • 3 CV 2Controls 1 and 3 provide coarse adjustment of thevoltages at o

Strany 4 - 5. User examples

A-176 Control Voltage SourceSystem A - 100doepfer45. User examplesExpanding other modules’ facilitiesModule A-176 is always going to be useful when

Strany 5

doepferSystem A - 100Control Voltage Source A-1765Fig. 2: Coarse and fine tuning an A-110 VCO.Recalling pre-set CV valuesCombined with an A-150 (o

Strany 6 - Control Voltage Source

A-176 Control Voltage SourceSystem A - 100doepfer66. Patch-SheetThe following diagrams of the module can helpyou recall your own Patches. They’re

Komentáře k této Příručce

Žádné komentáře